Then we click to Event List 2 and enter the name "Informational". Tick Opening
and Closing, and Autotest Report.
Event
Menu 6.11.1.1 or 4
System / Area
Channel Group 1
Event sent to
Channel Group
Menu 18 – Channel Groups
Channel Group 1
Channel 1
Channel 4
Channel Group sends event
Channel 6
to
every

Programming Instructions for Channels

Goal
Set up communication paths and destinations for delivering event messages.
Pre-conditions
Communicator must be programmed (see "Programming Instructions for
Communicator" on page 130).
Event Lists must be programmed (see "Programming Instructions for Event Lists"
on page 135).
Notes
Area Account Number will take priority over Account Number entered here for
Zone events. If no Area Account Number is entered then this number will be
used instead.
Next Channel must be a higher value than the current Channel Number.
Circular loops are not permitted.
Take note of the Sequence Attempts under Communicator > System Event
Reporting (6.11.2). This is the number of times xGenConnect will attempt the
sequence of Channels you set up in this section.
Channel set up for push notifications is automatically performed by the
UltraSync+ app when required. The panel will assign the next available
channel and matching event list number. No configuration via the web pages
or DLX900 is required.
xGenConnect Installation and Programming Guide
Menu 5 – Channels
Channel 1
Control Room 1
Event List = 1
Channel 4
Control Room 2
Event List = 1
Channel 6
Email
Event List = 2
Channel it contains
Menu 17 – Event Lists
Event List 1
Critical
Alarms
Bypass & Restore
AC Fail
Each channel checks to
see if the event is on its
Event List, if yes it will
attempt to send, if not
then it stops.
Event List 2
Informational
Open & Closes
Autotest