Interlogix xGenConnect NXG-4 Installation And Programming Manual page 152

Hide thumbs Also See for xGenConnect NXG-4:
Table of Contents

Advertisement

All alarms are reported to Control Room 1 and push notification goes to
UltraSync+ app installed on User 1's smartphone. Control room 1 has a backup
receiver.
When a channel receives an alarm message, xGenConnect checks that the
channel's Event List includes alarm messages and then attempts to deliver the
message via that channel.
When Channel 1/2/4 receives a low battery report, it is ignored because Event
List 1 does not include the "low battery" event.
Low priority alerts such as opening and closings, low batteries, and autotest
reports, are sent via Channel 6 as an email to a building manager. When
Channel 6 receives the alarm event it takes no further action because Event
List 2 does not include the "alarm" event.
Zone 3 in Alarm
Area sends
account number
and event to
Channel Group
Menu 18 – Channel Groups
Channel Group 1
Channel 1
Channel 4
Channel 6
Channel Group
sends Event to
every Channel it
contains
Menu 17 – Event Lists
Event List 1
Alarms
Event List 2
Event Lists
Opening & Closing
filter events
Low Battery
from passing
Autotest
through the
Channel
Event List 4
Alarms
Notice that Channel 2 is not selected in the Channel Group. The xGenConnect
will still deliver to this destination if Channel 1 cannot be reached. If Channel 2
was included in the Channel Group then the control room will receive duplicate
messages.
Next
Program your Areas and Zones.
140
After failing Channel Attempts on the last back up channel,
xGenConnect
will go back to the first Channel in the chain
Report Attempts = 2
Menu 5 – Channels
Channel 1
Control Room 1
Format = UltraSync
Event List = 1
Channel Attempts = 3
Next Channel = 2
Channel checks if the event is
on its Event List, if yes it will
attempt to send, if not then it
stops
Channel 4
UltraSync+ App
Format = Notifications
Destination = phone@u1
Event List = 4
Next Channel = 0
Channel 6
Email
Format = Email
Destination = Alex@home.com
Event List = 2
Next Channel = 0
xGenConnect Installation and Programming Guide
Channel 2
Control Room 1
Format = Backup
Event List = 1
Channel Attempts = 3
Next Channel = 0
If it does not succeed after
Channel Attempts, it will try
sending on the next Channel
xGenConnect
attempts to send event
via push notification to
smartphone. Event list
number always matches
channel number.