4.1.8 DEFEATING THE AUTO
TRACKING
TOP PREVIOUS NEXT
To defeat the Auto Tracking Function, place the instrument in the STOP mode and place a jumper
between TP6003 and TP6009 on the Main C.B.A. The tracking will be placed in the neutral position.