5.2.12.2 Reassembly Notes
TOP PREVIOUS NEXT
1.
Installation of Capstan Rotor Unit
A. Insert the Capstan Rotor Unit Shaft into the hole of the Capstan Holder Unit.
B. Place a support under the Capstan Rotor Unit shaft. Install the Stopper. Be careful not to
scratch the shaft or Capstan Holder Unit.
C. Remove the support. Press the top end of the shaft down so that the Stopper is properly
positioned.
You should be able to move the shaft up and down slightly when properly positioned.
Capstan Rotor Kit
A. Capstan Rotor Unit, Capstan Holder Unit, and Stopper are supplied as a Capstan Rotor Kit
only. (Kit No. VXPS0382K2) They are not reusable. Install all new parts.
B. Because even invisible scratches on the Capstan Rotor Unit shaft and the Capstan Holder Unit,
made when cutting the Stopper, could cause tape path instability.
TOP PREVIOUS NEXT
file:///E:/PV-9661_PV-9662/SVC/s0502120200.html [2006-01-28 11:10:21]
Fig. J11-2