file:///E:/PV-9661_PV-9662/SVC/s0603030000.html
6.3.3 PG SHIFTER ADJUSTMENT
TOP PREVIOUS NEXT
Purpose:
●
Determine the Video Head Switching Point during Playback.
Symptom of Misadjustment:
●
May cause Head Switching Noise and/or Vertical Jitter.
Test Point:
●
TP3001 (Main C.B.A.)
TP6205 (Main C.B.A.)
Adjustment:
●
R6201 (Main C.B.A.)
Specification:
●
T = 6 +/- 1H (0.38 +/- 0.06msec.)
Mode:
●
SP Playback
Equipment:
●
Oscilloscope,
VHS Alignment Tape (VFMS0003H6)
1. Connect the channel-1 scope probe to TP3001 and the channel-2 scope probe to TP6205.
Trigger from channel-2.
2. Playback the VHS alignment tape, and then connect TP6003 to GND to be in PG Shifter
Adjustment mode.
file:///E:/PV-9661_PV-9662/SVC/s0603030000.html (1 z 2) [2006-01-28 11:11:01]