Daikin INVERTER FTXM-V Series Engineering Data page 50

Split type air conditioners heat pump
Table of Contents

Advertisement

FTXM-V Series
Precautions on Installation
• Check the strength and level of the installation surface so that the unit does not cause
any operating vibrations or noise after installation.
• Fix the unit in place securely using foundation bolts, as in the figure. (Prepare 4
sets of 5/16 inch (M8) or 3/8 inch (M10) foundation bolts, nuts and washers; all sold
separately.)
• It is best to screw in the foundation bolts until their ends are 3/4 inch (20mm) from the
foundation surface.
Outdoor Unit Installation Diagram
Max. allowable piping length
** Min. allowable piping length
Max. allowable piping height
* Additional refrigerant required for refrigerant
pipe exceeding 49.2ft (15m) in length.
Gas pipe
Liquid pipe
Refrigerant piping must be kept to a minimum.
* Be sure to add the proper amount of additional refrigerant.
Failure to do so may result in reduced performance.
** The suggested shortest pipe length is 10ft (3m), in order to avoid
noise from the outdoor unit and vibration.
(Mechanical noise and vibration may occur depending on how
the unit is installed and the environment in which it is used.)
If strong wind blows into the air
discharge side from the front and
there is a danger that the fan may be
damaged, change the orientation of
the air discharge side of the outdoor
unit or use an air direction adjustment
grille (sold separately).
In sites with poor drainage, use
block bases for the outdoor unit.
Adjust foot height until the unit is
level. Otherwise, water leakage or
pooling of water may occur.
Refrigerant charge label
Please fill in with indelible ink,
the factory refrigerant charge of the product,
1
the additional refrigerant amount charged in the field and
2
+
the total refrigerant charge
1
2
on the refrigerant charge label supplied with the product.
Affix the refrigerant charge label near the manufacturer's label
after filling it out.
82-1/64ft (25m)
10ft (3m)
65-5/8ft (20m)
0.22oz/ft (20g/m)
O.D. 3/8 inch (9.5mm)
O.D. 1/4 inch (6.4mm)
Allow 11-13/16 (300)
of work space below
the ceiling surface.
unit : inch (mm)
The filled out label must be adhered in the
proximity of the product charging port.
2
5
48
Refrigerant piping must be protected from
physical damage.
Install a plastic cover or equivalent.
Allow space for piping
and electrical servicing.
If there is a danger of the unit falling or overturning,
fix the unit with foundation bolts, or with wire or
other means.
1 factory refrigerant charge of the
product: see unit name plate
2 additional refrigerant amount
charged in the field
=
kg
lb
1
3 total refrigerant charge
1
kg
lb
4 outdoor unit
=
2
2
5 refrigerant cylinder and manifold
for charging
kg
lb
1
+ =
2
1
3
4
EDUS042101
Wrap the insulation pipe with
finishing tape from bottom to top.
CAUTION
Keep the piping length between
10ft (3m) and 82-1/64ft (25m).
Stop valve cover
„ How to remove the stop
valve cover
1) Remove the screw on the
stop valve cover.
2) Slide the stop valve cover
downward to remove it.
„ How to attach the stop valve
cover
1) Insert the upper part of the
stop valve cover into the
outdoor unit.
2) Tighten the screw.
4
3P628775-2A

Hide quick links:

Advertisement

Table of Contents
loading

Table of Contents