Daikin FTXS60GV1B Operation Manual
Hide thumbs Also See for FTXS60GV1B:

Advertisement

MODELS
FTXS60GV1B
FTXS71GV1B
DAIKIN ROOM AIR CONDITIONER

OPERATION MANUAL

Advertisement

Table of Contents
loading

Summary of Contents for Daikin FTXS60GV1B

  • Page 1: Operation Manual

    DAIKIN ROOM AIR CONDITIONER OPERATION MANUAL MODELS FTXS60GV1B FTXS71GV1B...
  • Page 2: Table Of Contents

    CONTENTS READ BEFORE OPERATION Safety Precautions ......... 2 Names of Parts ..........4 Preparation before Operation......7 OPERATION AUTO · DRY · COOL · HEAT · FAN Operation ............. 10 Adjusting the Airflow Direction ..... 12 COMFORT AIRFLOW and INTELLIGENT EYE Operation ..... 14 POWERFUL Operation ........
  • Page 3: Read Before Operation

    Safety Precautions READ BEFORE OPERATION • Keep this manual where the operator can easily find them. • Read the precautions in this manual carefully before operating the unit. • The precautions described herein are classified as WARNING and CAUTION. They both contain important information regarding safety.
  • Page 4: Installation Site

    • Do not block air inlets nor outlets. Impaired airflow may result in insufficient performance or trouble. • Do not sit or place objects on the outdoor unit. Falling yourself or falling objects could cause injury. • Do not place objects that are susceptible to moisture directly beneath the indoor or outdoor units. Under certain conditions, condensation on the main unit or refrigerant pipes, air filter dirt or drain blockage may cause dripping, resulting in fouling or failure of the object concerned.
  • Page 5: Names Of Parts

    Names of Parts ■ Indoor Unit...
  • Page 6: Outdoor Unit

    ■ Outdoor Unit • Appearance of the outdoor unit may differ from some models. ■Indoor Unit 1. Air filter 13. Indoor unit ON/OFF switch: • Push this switch once to start operation. 2. Titanium apatite photocatalytic Push once again to stop it. air-purifying filter: •...
  • Page 7: Remote Controller

    Names of Parts ■ Remote Controller <Open the front cover> <ARC452A3> 1. Signal transmitter: 10. SWING button: • It sends signals to the indoor unit. • Flaps (horizontal blades) (page 12.) 2. Display (LCD): 11. SWING button: • It displays the current settings. •...
  • Page 8: Preparation Before Operation

    Preparation before Operation ■ To set the batteries 1. Slide the front cover to take it off. Position + and – correctly! 2. Set 2 dry batteries AAA.LR03 (alkaline). 3. Set the front cover as before. ■ To operate the remote controller •...
  • Page 9: To Set The Clock

    Preparation before Operation ■ To set the clock 1. Press • “ ” is displayed. • “ ” and “ ” blinks. 2. Press to set the current day of the week. 3. Press • “ ” blinks. 4. Press to set the clock to the present time.
  • Page 10 ■ Checks on remote controller settings • This remote controller is common to the heat pump model and cooling only model. Use the DIP switch on the remote controller to set the heat pump model or cooling only model. • Refer to the following explanation and make the setting as shown in the illustration.
  • Page 11: Auto · Dry · Cool · Heat · Fan Operation

    AUTO · DRY · COOL · HEAT · FAN Operation OPERATION The air conditioner operates with the operation mode of your choice. From the next time on, the air conditioner will operate with the same operation mode. ■ To start operation 1.
  • Page 12: To Change The Airflow Rate Setting

    ■ To change the airflow rate setting 5. Press AUTO or COOL or HEAT or FAN operation DRY operation 5 levels of airflow rate setting from “ ” to “ ” plus “ ” The airflow rate setting is not variable. “...
  • Page 13: Adjusting The Airflow Direction

    Adjusting the Airflow Direction You can adjust the airflow direction to increase your comfort. ■ To start auto swing Upper and lower airflow direction Press • “ ” is displayed on the LCD. • The flaps (horizontal blades) will begin to swing. Right and left airflow direction Press •...
  • Page 14 ■ To set the flaps or louvers at desired position • This function is effective while flaps or louvers are in auto swing mode. Press when the flaps or louvers have reached the desired position. • In the 3-D airflow, the flaps and louvers move in turn. •...
  • Page 15: Comfort Airflow And Intelligent Eye Operation

    COMFORT AIRFLOW and INTELLIGENT EYE Operation ■ COMFORT AIRFLOW operation The flow of air will be in the upward direction while in COOL operation and in the downward direction while in HEAT operation, which will provide a comfortable wind that will not come in direct contact with people.
  • Page 16 ■ To start operation Press and select the desired mode. • Each time the is pressed a different setting option is displayed on the LCD. • By selecting “ ” from the following icons, the air conditioner will be in COMFORT AIRFLOW operation combined with INTELLIGENT EYE operation.
  • Page 17 COMFORT AIRFLOW and INTELLIGENT EYE Operation NOTE ■ Notes on COMFORT AIRFLOW operation • The flap position will change, preventing air from blowing directly on the occupants of the room. • POWERFUL operation and COMFORT AIRFLOW operation cannot be used at the same time.
  • Page 18: Powerful Operation

    POWERFUL Operation POWERFUL operation quickly maximizes the cooling (heating) effect in any operation mode. You can get the maximum capacity. ■ To start POWERFUL operation 1. Press • POWERFUL operation ends in 20 minutes. Then the system automatically operates again with the previous settings which were used before POWERFUL operation.
  • Page 19: Outdoor Unit Quiet Operation

    OUTDOOR UNIT QUIET Operation OUTDOOR UNIT QUIET operation lowers the noise level of the outdoor unit by changing the frequency and fan speed on the outdoor unit. This function is convenient during night. ■ To start OUTDOOR UNIT QUIET operation 1.
  • Page 20: Econo Operation

    ECONO Operation ECONO operation is a function which enables efficient operation by limiting the maximum power consumption value. This function is useful for cases in which attention should be paid to ensure a circuit breaker will not trip when the product runs alongside other appliances.
  • Page 21: Off Timer Operation

    OFF TIMER Operation Timer functions are useful for automatically switching the air conditioner on or off at night or in the morning. You can also use OFF TIMER and ON TIMER in combination. ■ To use OFF TIMER operation • Check that the clock is correct. If not, set the clock to the present time.
  • Page 22: On Timer Operation

    ON TIMER Operation ■ To use ON TIMER operation • Check that the clock is correct. If not, set the clock to the present time. (page 8.) 1. Press • “ ” and setting time are displayed on the LCD. •...
  • Page 23: Weekly Timer Operation

    WEEKLY TIMER Operation Up to 4 timer settings can be saved for each day of the week. It is convenient if the WEEKLY TIMER is set according to the family’s life style. ■ Using in these cases of WEEKLY TIMER An example of WEEKLY TIMER settings is shown below.
  • Page 24 ■ To use WEEKLY TIMER operation Setting mode • Make sure the day of the week and time are set. If not, set the day of the week and time. (page 8.) Program 1 Program 2 Program 3 Program 4 [Monday] 25˚C 27˚C...
  • Page 25 WEEKLY TIMER Operation 6. Press to select the desired time. • The time can be set between 0:00 and 23:50 in 10 minute intervals. • To return to the ON/OFF TIMER mode setting, press • Go to step 9 when setting the OFF TIMER. 7.
  • Page 26 Setting Displays Day and number ON/OFF Time Temperature NOTE ■ Notes on WEEKLY TIMER operation • Do not forget to set the clock on the remote control first. • The day of the week, ON/OFF TIMER mode, time and set temperature (only for ON TIMER mode) can be set with WEEKLY TIMER.
  • Page 27 WEEKLY TIMER Operation Copy mode • A reservation made once can be copied another day of the week. The whole reservation of the selected day of the week will be copied. Program 1 Program 2 Program 3 Program 4 [Monday] 25˚C 27˚C 6:00...
  • Page 28 5. Press • The reservation will be copied to the selected day of the week. The whole reservation of the selected day of the week will be copied. • To continue copying the settings to other days of the week, repeat step 4 and step 5. 6.
  • Page 29 WEEKLY TIMER Operation ■ Confirming a reservation • The reservation can be confirmed. 1. Press • The day of the week and the reservation number of the current day will be displayed. 2. Press to select the day of the week and the reservation number to be confirmed.
  • Page 30 ■ To delete reservations The individual reservation • Refer to setting mode. (page 23.) When selecting desired mode at step 4 in setting mode, select “blank”. The reservation will be deleted. The reservations for each day of the week • This function can be used for deleting reservations for each day of the week.
  • Page 31: Note For Multi System

    Note for Multi System This system has one outdoor unit connected to multiple indoor units. ■ Selecting the operation mode A room B room 1. With the priority room setting present but inactive or not present. When more than 1 indoor unit is operating, priority is given to the first unit that was turned on.
  • Page 32 ■ OUTDOOR UNIT QUIET operation (page 18.) 1. With the priority room setting present but inactive or not present. When using the OUTDOOR UNIT QUIET operation feature with the Multi system, set all indoor units to OUTDOOR UNIT QUIET operation using their remote controllers. When clearing OUTDOOR UNIT QUIET operation, clear one of the operating indoor units using their remote controller.
  • Page 33: Care And Cleaning

    Care and Cleaning CARE CAUTION Before cleaning, be sure to stop the operation and turn the breaker off. Units ■ Indoor unit, outdoor unit and remote controller 1. Wipe them with dry soft cloth. ■ Front panel 1. Open the front panel. •...
  • Page 34: Air Filter

    Filters 1. Pull out the air filters. • Open the front panel. • Push a little upwards the tab at the center of each air filter, then pull it down. 1) Push Air filter 2) Pull down 2. Take off the titanium apatite photocatalytic air-purifying filter.
  • Page 35 Care and Cleaning 3-2 Titanium apatite photocatalytic air-purifying filter The titanium apatite photocatalytic air-purifying filter can be renewed by washing it with water once every 6 months. We recommend replacing it once every 3 years. [Maintenance] 3-2-1 Vacuum dusts, and soak in warm water or water for about 10 to 15 minutes if dirt is heavy.
  • Page 36: Before A Long Idle Period

    Check Check that the base, stand and other fittings of the outdoor unit are not decayed or corroded. Check that nothing blocks the air inlets and the outlets of the indoor unit and the outdoor unit. Check that the drain comes smoothly out of the drain hose during COOL or DRY operation. •...
  • Page 37: Troubleshooting

    Troubleshooting TROUBLESHOOTING • Troubleshooting measures are classified into the following two types on a remedial basis. Take an appropriate measure according to the symptom. Not trouble • These cases are not troubles. You may just continue using it. Check • Please check again before calling a repair person. The flaps does not start swing A sound is heard.
  • Page 38 The outdoor unit emits water or Operation stopped suddenly. steam. (OPERATION lamp flashes.) • Are the air filters clean? ■ In HEAT operation • Is there anything to block the air inlet or the • The frost on the outdoor unit melts into water outlet of the indoor and the outdoor units? or steam when the air conditioner is in defrost operation.
  • Page 39: Heat Pump Model

    Troubleshooting Operation stopped suddenly. Remote controller does not work (OPERATION lamp is on.) properly. • For system protection, the air conditioner ■ No remote controller signals are may stop operating on a sudden large displayed. voltage fluctuation. It automatically resumes ■...
  • Page 40 The ON/OFF TIMER does not The outdoor fan rotates while the operate according to the settings. air conditioner is not in operation. • Check if the ON/OFF TIMER and the ■ After operation is stopped WEEKLY TIMER are set to the same time. •...
  • Page 41: Call The Service Shop Immediately

    Troubleshooting Call the service shop immediately. WARNING ■ When an abnormality (such as a burning smell) occurs, stop operation and turn the breaker off. Continued operation in an abnormal condition may result in troubles, electric shocks or fire. Consult the service shop where you bought the air conditioner. ■...
  • Page 42: Fault Diagnosis

    Fault diagnosis. Fault diagnosis by remote controller In the ARC452A series, the temperature display sections on the main unit indicate corresponding codes. 1. When is held down for 5 seconds, a indication flashes on the “ ” temperature display section. 2.
  • Page 43 Troubleshooting LED ON OUTDOOR UNIT PCB 3MXS, 3MKS, 4MXS, 4MKS, 5MXS, 5MKS series GREEN MICROCOMPUTER MALFUNCTION NORMAL DETECTION LED-A LED1 LED2 LED3 LED4 LED5 DIAGNOSIS NORMAL CHECK INDOOR UNIT HIGH PRESSURE PROTECTOR WORKED OR FREEZE-UP IN OPERATING UNIT OR STAND-BY UNIT ∗...
  • Page 44 Two-dimensional bar code is a code for manufacturing. 3P248442-3 M08B300 (0911) HT...

This manual is also suitable for:

Ftxs71gv1bInverter ftxs60gv1bInverter ftxs71gv1b

Table of Contents