Daikin INVERTER FTXM-V Series Engineering Data page 211

Split type air conditioners heat pump
Table of Contents

Advertisement

FTXM-V Series
Tools Required for Installation
Tools Required for Installation
• Electric drill
Installation Procedure (1)
Installation Procedure (1)
WARNING
• Be sure to check that the power supply of the product is turned off.
1. Remove each component of the outdoor unit.
1) Remove the top plate.
2) Remove the stop valve cover.
3) Remove the protection plate.
4) Remove the front plate.
Front plate
(8 screws)
• Screw types for each component are indicated as below.
No icon: Hexagon tapping screw
: Truss head tapping screw
2. Remove the fan motor base.
1) Remove the fixing screws at the lower section of the fan motor base. (2 screws)
2) Remove the fan motor base together with the propeller fan and ensure that stress is not placed on the propeller fan
when placing them aside.
• Do not remove the fan motor harness.
• Ensure that the fan motor harness does not come into contact with the edges of the heat exchanger or other
components.
3
2 screws
1
• φ1/8 inch (φ3.2mm) drill
A
: Truss head tapping screw
• Phillips screwdriver
Top plate (4 screws)
Protection plate (3 screws)
View A
View A
The lugs of the fan motor
base are hooked on the
heat exchanger.
Appearance of the outdoor unit may differ from
some models.
209
EDUS042101
• Nippers
Stop valve cover (1 screw)
View A
Protection plate
Screws
3P647274-1
2021/02/25
13:50:57

Hide quick links:

Advertisement

Table of Contents
loading