Daikin INVERTER FTXM-V Series Engineering Data page 39

Split type air conditioners heat pump
Table of Contents

Advertisement

FTXM-V Series
01_EN_3P628775-1.fm Page 5 Monday, February 8, 2021 9:14 AM
Indoor Unit Installation
1.
Installing the mounting plate
The mounting plate should be installed on a wall which can support the weight of the indoor unit.
1)Temporarily secure the mounting plate to the wall, make sure that the plate is completely level, and mark the drilling points
on the wall.
2)Secure the mounting plate to the wall with screws.
Recommended mounting plate retention spots and dimensions
09/12 class
Recommended mounting plate
retention spots (7 spots in all)
2-11/16 (68)
Place the pipe port
cover in this pocket.
18/24 class
Recommended mounting
plate retention spots
(7 spots in all)
2-11/16 (68)
* Depending on the model, the actual distance between the liquid pipe end and gas pipe end may differ from the distance between those symbols on the
mounting plate (the distance listed in this manual).
Always measure the actual distance between the liquid pipe end and gas pipe end before installing refrigerant pipes.
5
4-3/4 (120)
5-7/8 (150)
6-5/16 (160)
15-7/16 (392)
The removed pipe port cover can be kept in the mounting plate pocket.
4-3/4 (120)
5-7/8 (150)
Liquid pipe end
6-5/16 (160)
21-5/8 (550)
Place a leveler
on these tabs.
6-1/4 (158)
11-1/2 (292)
Liquid pipe end
Gas pipe end
2-9/16 (65*)
15-1/4 (387)
15-7/16 (392)
36-1/4 (920)
A
Mounting
plate
Removed pipe
port cover
Place a leveler
on these tabs.
Gas pipe end
2-9/16 (65*)
15-1/4 (387)
21-5/8 (550)
43-5/16 (1100)
37
4-5/8 (118)
Through-the-wall
hole φ2-9/16 (65)
9-1/16 (230)
6-5/16 (160)
Drain hose
position
2-11/16 (68)
Use a tape measure as
shown.
Position the end of the
tape measure at
.
4-5/8 (118)
Through-the-wall
hole φ3-1/8 (80)
9-1/16 (230)
6-5/16 (160)
Drain hose
position
2-11/16 (68)
unit: inch (mm)
EDUS042101
3P628775-1

Hide quick links:

Advertisement

Table of Contents
loading

Table of Contents