Daikin INVERTER FTXM-V Series Engineering Data page 23

Split type air conditioners heat pump
Table of Contents

Advertisement

FTXM-V Series
Cooling (60 Hz, 230 V)
AFR
22
BF
0.27
Temp: Celsius / TC, SHC, PI: kW
INDOOR
EWB EDB
10
°C
°C
TC
SHC
14.0
20.0
5.90
4.52
0.89
16.0
22.0
6.14
4.43
0.90
18.0
25.0
6.38
4.66
0.90
19.4
26.7
6.50
4.93
0.91
22.0
30.0
6.87
4.75
0.92
24.0
32.0
7.11
4.63
1.14
Temp: Fahrenheit / TC, SHC: kBtu/h / PI: kW
INDOOR
EWB EDB
50
°F
°F
TC
SHC
57.2
68.0 20.12 15.42 0.89 18.44 14.60 1.10 16.76 13.81 1.32 15.93 13.41 1.42 15.83 13.37 1.88 15.69 13.30 2.48
60.8
71.6 20.95 15.12 0.90 19.27 14.36 1.11 17.59 13.61 1.32 16.76 13.24 1.43 16.70 13.21 1.89 16.61 13.18 2.49
64.4
77.0 21.78 15.88 0.90 20.10 15.17 1.12 18.42 14.48 1.33 17.59 14.14 1.44 17.57 14.13 1.90 17.54 14.12 2.50
67.0
80.0 22.19 16.81 0.91 20.51 16.13 1.12 18.84 15.46 1.33 18.00 15.13 1.44 18.00 15.13 1.90 18.00 15.13 2.50
71.6
86.0 23.43 16.20 0.92 21.76 15.60 1.13 20.08 15.01 1.34 19.24 14.72 1.45 19.24 14.72 1.91 19.24 14.72 2.51
75.2
89.6 24.26 15.78 1.14 22.59 15.23 1.14 20.91 14.70 1.35 20.07 14.43 1.46 20.07 14.43 1.92 20.07 14.43 2.52
Heating (60 Hz, 230 V)
AFR
22.0
Temp: Celsius / TC, PI: kW
INDOOR
EDB
-25
°C
TC
PI
15.0
5.29
3.01
21.1
4.75
3.10
22.0
4.52
3.12
24.0
3.75
2.44
25.0
3.37
2.12
27.0
2.60
1.55
Temp: Fahrenheit / TC: kBtu/h / PI: kW
INDOOR
EDB
-13
°F
TC
PI
59.0
18.06
3.01
70.0
16.20
3.10
71.6
15.42
3.12
75.2
12.79
2.44
77.0
11.48
2.12
80.6
8.86
1.55
Symbols:
AFR
: Airflow rate
BF
: Bypass factor
EWB
: Entering wet bulb temp.
EDB
: Entering dry bulb temp.
TC
: Total capacity
SHC
: Sensible heat capacity
PI
: Power input
OUTDOOR TEMPERATURE (°CDB)
20
PI
TC
SHC
PI
TC
5.40
4.28
1.10
4.91
5.65
4.21
1.11
5.16
5.89
4.45
1.12
5.40
6.01
4.73
1.12
5.52
6.38
4.57
1.13
5.89
6.62
4.46
1.14
6.13
OUTDOOR TEMPERATURE (°FDB)
68
PI
TC
SHC
PI
TC
OUTDOOR TEMPERATURE (°CWB)
-20
-15
TC
PI
TC
PI
6.00
3.21
6.75
3.42
5.54
3.31
6.33
3.52
5.35
3.35
6.16
3.56
5.17
3.38
6.00
3.59
5.08
3.40
5.91
3.61
4.36
2.74
5.75
3.65
OUTDOOR TEMPERATURE (°FWB)
-4
5
TC
PI
TC
PI
20.48
3.21
23.02
3.42
18.90
3.31
21.60
3.52
18.27
3.35
21.03
3.56
17.64
3.38
20.47
3.59
17.32
3.40
20.18
3.61
14.87
2.74
19.61
3.65
Notes:
(m³/min.)
1.
capacities and power input (Heating).
2.
TC, PI and SHC must be calculated by interpolation using the figures in the above
(°C) / (°F)
tables.
(°C) / (°F)
(Figures out of the tables should not be used for calculation.)
(kW) / (kBtu/h)
3.
Capacities are based on the following conditions.
Corresponding refrigerant piping length : 25 ft (7.5 m)
(kW) / (kBtu/h)
Level difference : 0 ft (0 m)
(kW)
4.
Airflow rate (AFR) and Bypass factor (BF) are tabulated above table.
30
35
SHC
PI
TC
SHC
4.05
1.32
4.67
3.93
1.42
3.99
1.32
4.91
3.88
1.43
4.24
1.33
5.15
4.14
1.44
4.53
1.33
5.28
4.43
1.44
4.40
1.34
5.64
4.31
1.45
4.31
1.35
5.88
4.23
1.46
86
95
SHC
PI
TC
SHC
-10
-5
TC
PI
TC
PI
7.31
3.38
7.88
3.33
6.93
3.47
7.53
3.41
6.78
3.50
7.39
3.45
6.63
3.54
7.25
3.48
6.56
3.56
7.18
3.50
6.41
3.59
7.05
3.53
14
23
TC
PI
TC
PI
24.93
3.38
26.88
3.33
23.65
3.47
25.70
3.41
23.14
3.50
25.22
3.45
22.63
3.54
24.75
3.48
22.37
3.56
24.52
3.50
21.86
3.59
24.04
3.53
shows nominal (rated) capacities and power input (Cooling) and MAX
21
40
PI
TC
SHC
PI
TC
4.64
3.92
1.88
4.60
4.89
3.87
1.89
4.87
5.15
4.14
1.90
5.14
5.28
4.43
1.90
5.28
5.64
4.31
1.91
5.64
5.88
4.23
1.92
5.88
104
PI
TC
SHC
PI
TC
0
6
TC
PI
TC
PI
8.46
3.28
9.16
3.23
8.13
3.36
8.85
3.30
8.00
3.39
8.73
3.33
7.87
3.43
8.61
3.36
7.81
3.44
8.55
3.37
7.68
3.47
8.42
3.40
32
43
TC
PI
TC
PI
28.85
3.28
31.24
3.23
27.74
3.36
30.20
3.30
27.30
3.39
29.78
3.33
26.86
3.43
29.37
3.36
26.64
3.44
29.16
3.37
26.19
3.47
28.74
3.40
EDUS042101
46
SHC
PI
3.90
2.48
3.86
2.49
4.14
2.50
4.43
2.50
4.31
2.51
4.23
2.52
115
SHC
PI
15.5
TC
PI
11.06
3.48
10.75
3.56
10.63
3.59
10.51
3.62
10.44
3.63
10.32
3.66
60
TC
PI
37.72
3.48
36.68
3.56
36.26
3.59
35.85
3.62
35.64
3.63
35.22
3.66
C: 3D133619

Hide quick links:

Advertisement

Table of Contents
loading

Table of Contents