Daikin INVERTER FTXM-V Series Engineering Data page 36

Split type air conditioners heat pump
Table of Contents

Advertisement

FTXM-V Series
01_EN_3P628775-1.fm Page 2 Monday, February 8, 2021 9:14 AM
• Make sure that a separate power supply circuit is provided
for this unit and that all electrical work is carried out by
qualified personnel licensed or certified in their jurisdiction
according to local, state, and national regulations. An
insufficient power supply capacity or improper electrical
construction may lead to electric shock or fire.
• Make sure that all wiring is secured, that specified wires are
used, and that no external forces act on the terminal
connections or wires. Improper connections or installation
may result in fire.
• When wiring, position the wires so that the electrical wiring
box cover can be securely fastened. Improper positioning of
the electrical wiring box cover may result in electric shock,
fire, or the terminals overheating.
• Before touching electrical parts, turn off the unit.
• The circuit must be protected with safety devices in
accordance with local and national codes, i.e. a circuit
breaker.
• Securely fasten the outdoor unit terminal cover (panel). If
the terminal cover/panel is not installed properly, dust or
water may enter the outdoor unit causing fire or electric
shock.
• When installing or relocating the system, keep the refrigerant
circuit free from substances other than the specified
refrigerant (R32) such as air. Any presence of air or other
foreign substance in the refrigerant circuit can cause an
abnormal pressure rise or rupture, resulting in injury.
• Do not change the setting of the protection devices. If the
pressure switch, thermal switch, or other protection device is
shorted and operated forcibly, or parts other than those
specified by Daikin are used, fire or explosion may occur.
• When installing or relocating the air conditioner, do not let
any other substances besides R32, such as air, enter the
refrigerant circuit. The presence of air or foreign matter in
the refrigerant circuit causes an abnormal pressure rise,
which may result in equipment damage and even injury.
• Do not use means to accelerate the defrosting process (if
possible) or to clean, other than those recommended by the
manufacturer.
• The appliance must be stored in a room without
continuously operating ignition sources (for example: open
flames, an operating gas appliance or an operating electric
heater).
• Do not pierce or burn.
• Be aware that refrigerants may not contain an odor.
• Comply with national gas regulations.
CAUTION
• Do not touch the switch with wet fingers. Touching a switch
with wet fingers can cause electric shock.
• Do not allow children to play on or around the unit to prevent
injury.
• Wear adequate personal protective equipment (protective
gloves, safety glasses,...) when installing, maintaining or
servicing the system.
• The heat exchanger fins are sharp enough to cut. To avoid
injury, wear gloves or cover the fins while working around
them.
• Do not touch the refrigerant pipes during and immediately
after operation as the refrigerant pipes may be hot or cold,
depending on the condition of the refrigerant flowing through
the refrigerant piping, compressor, and other refrigerant
cycle parts. Your hands may suffer burns or frostbite if you
touch the refrigerant pipes. To avoid injury, give the pipes
time to return to normal temperature or, if you must touch
them, be sure to wear proper gloves.
• Install drain piping to ensure proper drainage. Improper drain
piping may result in water leakage and property damage.
• Insulate piping to prevent condensation.
• Be careful when transporting the product.
• Do not turn off the power immediately after stopping
operation. Always wait for at least 5 minutes before turning
off the power. Otherwise, water leakage may occur.
• Do not use a charging cylinder. Using a charging cylinder
may cause the refrigerant to deteriorate.
• Refrigerant R32 in the system must be kept clean, dry, and
tight.
(a) Clean and Dry -- Foreign materials (including mineral oils
such as SUNISO oil or moisture) should be prevented
from getting into the system.
(b) Tight -- R32 does not contain any chlorine, does not
destroy the ozone layer, and does not reduce the earth's
protection again harmful ultraviolet radiation. R32 can
contribute to the greenhouse effect if it is released.
Therefore take proper measures to check for the tightness
of the refrigerant piping installation. Read the chapter
Refrigerant Piping Work and follow the procedures.
• The indoor unit is for R32. See the catalog for outdoor
models that can be connected. Normal operation is not
possible when connected to non-compatible outdoor units.
• Remote controller (wireless kit) transmitting distance can be
shorter than expected in rooms with electronic fluorescent
lamps (inverter or rapid start types). Install the indoor unit far
away from fluorescent lamps as much as possible.
• Do not install the air conditioner or heat pump in the
following locations:
(a) Where a mineral oil mist or oil spray or vapor is produced,
for example, in a kitchen.
Plastic parts may deteriorate and fall off or result in water
leakage.
(b) Where corrosive gas, such as sulfurous acid gas, is
produced.
Corroding copper pipes or soldered parts may result in
refrigerant leakage.
(c) Near machinery emitting electromagnetic waves.
Electromagnetic waves may disturb the operation of the
control system and cause the unit to malfunction.
(d) Where flammable gas may leak, where there is carbon fiber,
or ignitable dust suspension in the air, or where volatile
flammables such as thinner or gasoline are handled.
Operating the unit in such conditions can cause a fire.
• Take adequate measures to prevent the outdoor unit from
being used as a shelter by small animals. Small animals
making contact with electrical parts can cause malfunctions,
smoke, or fire. Instruct the user to keep the area around the
unit clean.
• Servicing shall be performed only as recommended by the
manufacturer and licensed or certified in their jurisdiction.
NOTE
• The indoor unit should be positioned where the unit and inter-
unit wires (outdoor to indoor) are at least 3.3ft (1m) away from
any televisions or radios. (The unit may cause interference with
the picture or sound.) Depending on the radio waves, a distance
of 3.3ft (1m) may not be sufficient to eliminate the noise.
• Dismantling the unit, treatment of the refrigerant, oil and
additional parts must be done in accordance with the
relevant local, state, and national regulations.
• Only use tools for R32 or R410A, such as a gauge manifold,
charge hose, gas leak detector, reverse flow check valve,
refrigerant charge base, vacuum gauge, or refrigerant
recovery equipment.
• If the conventional refrigerant and refrigerator oil are mixed
in R32, the refrigerant may deteriorate.
• As maximum allowable pressure is 604psi (4.17MPa), the
wall thickness of field-installed pipes should be selected in
accordance with the relevant local, state, and national
regulations.
34