10-8
ELECTRICAL SYSTEM
INSPECTION
BATTERY CURRENT LEAKAGE
• Open the seat.
• Remove the tool bag.
• Remove the battery cover 1 with starter relay.
• Turn the ignition switch to the "OFF" position.
• Disconnect the - battery lead wire 2.
Measure the current between - battery terminal and the - bat-
tery lead wire using the multi circuit tester. If the reading
exceeds the specified value, leakage is evident.
09900-25008: Multi circuit tester set
Tester knob indication: Current (
Battery current (leak): Under 3.0 mA
* Because the current leak might be large, turn the
tester to the high range first to avoid tester damage.
* Do not turn the ignition switch to the "ON" position
when measuring current.
When checking to find the excessive current leakage, remove
the couplers and connectors, one by one, checking each part.
, 20 mA)