Figure 23: Chassis Status Leds On Qfx10002 Models; Table 17: Chassis Status Leds On A Qfx10002 Switch - Juniper QFX10002 Hardware Manual

Hide thumbs Also See for QFX10002:
Table of Contents

Advertisement

QFX10002 Switch Hardware Guide

Table 17: Chassis Status LEDs on a QFX10002 Switch

Name
PWR–Alarm
STA–Status
48

Figure 23: Chassis Status LEDs on QFX10002 Models

1—
PWR
2—
MJR
Table 17 on page 48
describes the chassis status LEDs on a QFX10002, their colors and
states, and the status they indicate.
Color
Unlit
Green
Yellow
Unlit
Green
Green
Yellow
1
2
3
4
3—
MIN
4—
STA
State
Description
Off
The switch is powered off; no power to
the device.
On steadily
Power is working correctly.
Blinking
There is a problem with chassis power.
Power off the QFX10002 by setting the
AC power source outlet to the OFF (O)
position, or unplugging the AC power
cords. Correct any voltage issues. Power
on the QFX10002 and monitor the power
supply and fan LEDs to help determine
where the error is occurring. If there is any
CPU power failure, the system will not
boot.
Off
The switch is powered off or halted.
On steadily
Junos OS for QFX Series is loaded on the
switch.
Blinking
The beacon feature is enabled on the
switch. This feature is enabled using the
request chassis beacon
Blinking
The switch detects a fault.
command.