Table 47: QFX10002 Chassis Alarm Messages

Component
Alarm Type
Fans
Major (red)
Minor (yellow)
Copyright © 2019, Juniper Networks, Inc.
CLI Message
Fan Failure
Fan I2C Failure
Fan fan-number Not Spinning
Fan/Blower Absent
Chapter 5: Troubleshooting
Recommended Action
Replace the fan module and report the
failure to customer support.
Check the system log for one of the
following messages and report the error
message to customer support:
CM ENV Monitor: Get fan speed failed
fan-number is NOT spinning @ correct
speed
, where
fan-number
can be 1, 2, or
3.
Remove and check the fan module for
obstructions, and then reinsert the fan
module. If the problem persists, replace
the fan module.
Check the system log for the message
, where
fan-number Absent
fan-number
can be 1, 2, or 3.
Install the fan module.
.