Related
Documentation
QFX10002 Cooling System
QFX10002 Cooling System Description and Airflow
Copyright © 2019, Juniper Networks, Inc.
Connecting a QFX10002 to a Management Ethernet Device on page 98
QFX10002 Cooling System Description and Airflow on page 51
QFX10002 Fan Module LED on page 54
The cooling system in a QFX10002 consists of three 80-W fan modules in a fan tray and
two counter-rotating fans housed in each of the power supplies.
The QFX10002 brings air into the vents in the port panel and exhausts warmed air through
the field-replaceable units (FRU) panel. This type of airflow is known as airflow out or
port-to-FRU airflow.
This topic describes:
Fan Modules on page 51
Fan Module Status on page 53
Fan Modules
The fan modules in a QFX10002 are hot-removable and hot-insertable FRUs designed
for port-to-FRU airflow. The fan modules numbered
tray located next to the power supplies. Each fan module slot has a fan icon next to it.
NOTE:
Fan modules designed for the QFX10002-60C
have a different orientation than the QFX10002-72Q or QFX10002-36Q
(Figure 24 on page
and the
Air Out
Figure 24 on page 51
shows the 2-U fan module for the QFX10002 models.
Figure 24: Fan Module for the QFX10002-72Q and QFX10002-36Q
51). Ensure you use the correct fan module for each model
label is facing up and is readable.
Chapter 1: Overview
0
through
2
are installed in the fan
(Figure 25 on page
52)
51