Chapter 4: Menu reference
device (in the Item field) by entering the number of the device (for example,
input) directly into the field.
The events used as macro conditions are pre-defined as listed in Appendix A
"Door controller events" on page 117. Some can only be used for macro inputs,
some for macro outputs, and others may be used for either inputs or outputs.
The input can be set to Disabled to disable the condition.
The logic connecting the four logic inputs can be programmed for AND or OR
functions. A NAND or NOR function can be achieved by inverting the logic of the
particular input with the NO check box.
Activate
This programmed DGP event will be activated when the result of the logic
equation is true and any timing conditions are met. Select the type of entity to
activate (for example, Door lock), then select the specific device the DGP event
relates to (for example, door) by entering the number of the device (for example,
input) directly into the field.
The output can be set to Disabled to disable its activation.

Scheduled actions tab

To configure a door schedule in Downloader, click Scheduled actions tab.
Select the appropriate door schedule and click Browse "..." to open the Schedule
form.
On the Schedule form, click Remove to remove the schedule data.
The following settings are available.
Door number
Enter the door number on the CDC4 to select the door.
Enabled
Select On to enable the door schedule.
Start date
Enter the start date for the active period.
Use end date
Select On to enable the use of an end date for the active period.
End date
Enter the end date for the active period, if required.
CDC4 Door Controller Installation and Programming Manual
91