Chapter 4: Menu reference
external input fields. Program each input location using the scheme described in
the "Flexible device locations" section on page 63.

Access tab

Access options for a door are configured on the Access tab of the Doors form.
The following settings are available.
Door name
When a door is created, it is given the default name "Door <n>", where <n> is the
door number. Enter this menu to edit the current name.
Door type
The Door type field is for future use. Currently, the door type is set as Door and
cannot be changed.
Unlock time
Program the amount of time for the door to unlock when a user enters a valid
card or PIN at the door reader. The user is then able to open the unlocked door
during the access time.
Enter the time in seconds.
Extended unlock time
Program the amount of time for the door to unlock when a user, with the "Use
extended shunt time" flag enabled, presents a valid card or PIN at the door
reader. The user is then able to open the unlocked door during the extended
access time.
Enter the time in seconds.
Dual Badge Time
Note:
By default, if two-badge functionality is enabled, only the second user is
reported as having accessed a door. Thus if a visitor and an accompanying
guard badge their cards to open a door, only the guard is considered as having
accessed the door.
If two-badge functionality is used, you can define the amount of time permitted
between a visitor and an accompanying guard badging their cards to open a
door, or between the first and second instances of badging when two-badge
unlock is used.
If the time expires before the second badging, then the door is not unlocked and
the operation must be recommenced.
Enter the time in seconds.
CDC4 Door Controller Installation and Programming Manual