Chapter 2: System functions
If the door state is overridden (for example, by management software or a
user badging a card), then at the conclusion of the overriding state, the door
will revert to its default state. The start action will no longer have any bearing
on the state of the door.
The possible door actions, which can be configured to execute at the start time or
the end time, are:
Unlock
Lock
Disable
Enable
Door schedules are programmed in Downloader on the Expander form >
Scheduled Actions tabs. See "Scheduled actions tab" on page 91 for instructions.
Notes
With reference to the priorities for overriding a door state (see the "Door state
priorities" section on page 69), a door schedule end action has a lower priority
than any override schedule in effect, unless the end action is to disable the
door.
A door schedule will not override the operation of a door schedule that has
already started.
Door schedules that have reached the end of their active period can be
deleted via management software.
Door Unlock action
If the start action is Unlock, then the door will unlock at the start time and remain
unlocked for the specified action duration (or indefinitely if there is no action
duration configured).
During this time if an existing override schedule ends (the door programmed
unlock schedule), then the door will remain unlocked.
When the action duration has completed, the end action will occur. However, if
the start action ends and an existing override schedule is active (the door
programmed unlock schedule), then the door will remain unlocked.
A manual lock command sent from management software will lock the door and
cancel the start action.
If the door has "Door unlock after entry" enabled (see the "Door unlock after
entry" section on page 103), the door will not unlock until a valid user PIN or card
is presented at the door.
Door Lock action
If the start action is Lock, then the door will lock at the start time and remain
locked for the specified action duration (or indefinitely if there is no action
duration configured).