Programming IP communications
If the Door Controller is operating in IP Extended mode, then set up IP
communications on the CDC4.
Configuring Ethernet
Configure Ethernet communications on the CDC4. Using Downloader, follow
these steps:
1. Click the Expander devices list on the Panel data window to open the
Expander list.
2. Select the CDC4 expander.
3. On the Details tab, configure Onboard Ethernet option. Click Browse "..." and
provide all the connection details: enable Ethernet, and provide door
controller IP configuration.
Configuring communications path
Configure an IP communications path on the CDC4 for management software.
Using Downloader, follow these steps:
1. On the expander list, select the CDC4 and select Comm paths tab to open
the Comm paths form.
2. Select the required path and Click Browse "..." to configure it. In the Common
Data Path tab, set Enabled to On. In the IP path tab, set IP protocol to
TCP/IP, Client to Server, Dynamic computer address to On, and Listening
and Host ports to 3001.
The configured communications path can be used by the management software.
If required, set up additional communications paths by repeating the steps in this
section with a different communications path.