Earthing The Enclosure; Accessories - Interlogix CDC4 Installation And Programming Manual

Door controller
Table of Contents

Advertisement

Chapter 1: Installation
5. Reinsert the power lead into the power inlet.

Earthing the enclosure

To comply with safety regulations the enclosure base and door must be earthed.
An external earth connection is provided by the transformer. If the transformer is
not fitted, or not used, an alternative electrical earth must be provided.
To earth the enclosure base, attach the earth cable (provided) to the tab inside
the enclosure and to one of the transfer earth tabs.
To earth the door, attach the earth cable (provided) to the remaining tab inside
the enclosure and then to the tab inside the door.

Accessories

Power entry guard plate
The power entry guard plate is used to close out the cable entry cut-out. The
entry can be completely blocked or partially block to allow the power cable to
enter the enclosure.
Cable entry guard plate
The cable entry guard plate is used to close out the cable entry cut-out. The entry
can be configured, using this plate, to accept 50x50, 50x25 conduit or to be
blocked completely.
Tamper kit
The tamper kit can be installed so that an alarm is raised if the enclosure is
opened or removed from the wall.
Transformer retainer
The transformer retainer is used to hold the transformer in place.
6
CDC4 Door Controller Installation and Programming Manual