Specifications
Mains power specifications
Mains input voltage
Transformer output
Power supply specifications
Power supply voltage
Main board consumption
Auxiliary power output (AUX. POWER) 13.8 V
Door lock relay switching capacity:
Maximum (resistive/load)
Minimum
Battery power output (BAT)
Battery type
Ethernet connection
Supported standard
Speed
Duplex
Cabling
Autonegotiation
Environmental
Storage temperature
Operating temperature
Maximum relative humidity
IP protection grade
Colour
Dimensions (W x H x D)
Weight
Fuses
Mains, mains fuse
Battery
CDC4 Door Controller Installation and Programming Manual
230 VAC +10%, −15%, 50 Hz 10%
19 VAC, SELV Class I power limited
0.2 V
13.8 V
226 mA (whilst battery voltage is 12.0 V)
Note:
Active Ethernet adds 25 mA. Each active relay
coil adds 55 mA.
See also "Output fusing and user current draw" on page
38.
0.2 V, 1 A max.
3 A, 30 V DC
100 mA, 5 V DC
0.2 V, 2.5 A max.
13.8 V
Lead acid rechargeable:
12 Ah, 12 V nom. (BS130N)
18 Ah, 12 V nom. (BS131N)
26 Ah, 12 V nom. (BS129N)
IEEE 802.3u
10BASE-T or 100BASE-TX
Half-duplex and full-duplex
FTP (foiled twisted pair) Cat 5e cable or better
MDIX
−20 to +80°C
0 to +50°C
93% noncondensing
IP31
Beige
409 x 593 x 112 mm
10.22 kg
M205 (5x20 mm) 1 A 250 VAC slow blow
3AG/3AB (6x32 mm) 8 A 250 VAC slow blow
Chapter 1: Installation