Chapter 4: Menu reference
HSU Warning Output BUS
The defined output is active when the warning timer set in "HSU Warning Time"
on page 93 is running.
HSU Alarm output BUS
The defined output activates when the warning time set in "HSU Warning Time"
on page 93 expires and an alarm is raised.
The output is deactivated when the number of HSU increases to the minimum
threshold, or when all users leave this region.
Schedule
The schedule is used for the releasing users from the region. See "Release users
from region on timezone start" below and "Release users from region on
timezone end" below.
Alarm Levels 1..6
Select alarm control levels for the selected region.
The option has no effect if "Alarm control by region" below is disabled.
High Security Users
Activate or deactivate the HSU functionality in the selected region.
If the functionality is disabled, all HSU related options described above have no
effect.
Alarm control by region
If the alarm control by region is enabled, the last user leaving the region assigned
to door automatically sets the area, and the first user entering the region unsets
it.
This functionality is described in "Alarm control by region" on page 55.
Delayed Arming
If enabled, the alarm control by region will cause a delayed set prompt prior to
the area set.
Release users from region on timezone start
The users are removed from the region every time the "Schedule" above is
started (each segment becomes active).
Release users from region on timezone end
The users are removed from the region every time a segment of the "Schedule"
above ends.
94
CDC4 Door Controller Installation and Programming Manual