Chapter 5. Configuring Network Options
1=LOCAL
3=CONFIG
2=REMOTE ENTER ADDRESS
When operating on a DDS network, the timing should be FROM NET-
WORK. On a point-to-point private network, one DSU III ARdc must be
set for MASTER, and the other set for FROM NETWORK. Table 5-5
shows the equivalent AT commands for setting the clock source.
Select Master timing only if the circuit has no timing source (for example, two
DSUs and a crossover cable).
Front
Panel
1=MASTER
2=FROM NETWORK
5-6
1=NETWORK OPT.
2=DTE OPTIONS
3=TEST OPTIONS
4=DIAL OPTIONS
5=MANUAL COMMAND
Figure 5-5. Setting the Clock Source
Table 5-5. Clock Source Commands
AT
Command
_X0
DSU is the master timing source
_X1
Network Rx signal is timing source
DSU III ARdc User Manual
1=LOOP RATE
2=NETWORK ADDR
3=REMOTE CONFIG.
4=NETWORK TYPE
5=CLOCK SOURCE
1=MASTER
2=FROM NETWORK
Description
61200270L1-1