Chapter 11. Testing and Troubleshooting

Troubleshooting New Installs or Existing Circuits

If your DSU ....
is suspected of having problems
is receiving excessive errors requiring retrans-
mission of data
continues to receive excessive errors requir-
ing retransmission of data
If an external BERT tester is available, these additional tests may be per-
formed:
If the unit fails any of these tests or the problem has not been determined,
contact ADTRAN Technical Support; see inside back cover of this manual.
11-8
DTE & Loop Test
DTE Only Test
Loop Only Test
DSU III ARdc User Manual
then...
perform a Self Test to determine the unit is in
good health.
perform a DTE with Test Pattern Test
to determine if the unit's internal transmitter
and receiver is operating error free.
perform a Remote Test to verify an error-free
connection between the local and remote
unit. Run the test using all available test pat-
terns.