Remote configuration is a very useful feature of the ADTRAN DSU IQ. Using a VT 100
terminal session and local unit, a user may configure the units at remote sites. This
process is non-disruptive to customer data. For example, in Figure 1 the user could
remotely configure the DSU IQ at remote site #1 or remote site #2 from the host DSU IQ.
In addition, either remote DSU IQ could remotely configure the host DSU IQ. It should
be noted that due to the fact that there is not a virtual circuit connecting the two remote
sites, neither remote site DSU IQ could remotely configure the other remote site DSU IQ.
The host site communicates with remote site #1 via DLCI 16 and remote site #2 via
DLCI 17. Remote site #1 sends data to the host site via DLCI 18 and remote site #2 sends
data to the host site via DLCI 19.
Directions for the Remote Configuration Process
Directions for the Remote Configuration Process
Directions for the Remote Configuration Process
Directions for the Remote Configuration Process
1. Connect the straight-through RJ45 silver satin cable provided by ADTRAN to the
control port of the unit. Connect the other end of the cable to the RJ45 to DB25
adapter provided. Only use the ADTRAN adapter part number 3196.ADPT005.
Other vendor adapters will not work. Connect the DB25 end of the adapter to the
COM port of your computer. If your computer COM port is a DB9, a DB9 to
DB25 adapter will be necessary.
Figure 1
Figure 1
Figure 1
Figure 1

Advertisement

loading

Summary of Contents for ADTRAN DSU IQ

  • Page 1 For example, in Figure 1 the user could remotely configure the DSU IQ at remote site #1 or remote site #2 from the host DSU IQ. In addition, either remote DSU IQ could remotely configure the host DSU IQ. It should be noted that due to the fact that there is not a virtual circuit connecting the two remote sites, neither remote site DSU IQ could remotely configure the other remote site DSU IQ.
  • Page 2: Login Menu

    2. Open a terminal emulation program using the parameters 9600 bps, 8 data bits, 1 stop bit, and no parity. At this point, you should see a blank screen. Press return several times and the login screen shown in Figure 2 will appear. LOGIN MENU ADTRAN DSUIQ LOCAL ______________________________________________________________________________ 1 - LOCAL LOGIN...
  • Page 3: Remote Login

    DLCI on which the data is sent to the remote site, not the DLCI of the remote site. Using Figure 1, when the user at the host site is remotely configuring the DSU IQ at remote site 1, the remote DLCI would be 16. When the user at remote site #1 is remotely configuring the host DSU IQ, the remote DLCI would be 18.
  • Page 4 5. Press any key and the screen shown in Figure 5 will appear. ------------------------------------------------------------------------------ Enter password: ------------------------------------------------------------------------------ Figure 5 Figure 5 Figure 5 Figure 5 6. The default password is ADTRAN. It is not case sensitive. The screen shown in Figure 6 will then appear.
  • Page 5 Verify that the correct computer COM port is being used. This may be accomplished by connecting to another device, such as a modem. Verify the proper ADTRAN RJ45-DB25 adapter is connected. The adapter is labeled with ADTRAN part number 3196.ADPT005.
  • Page 6 Figure 7 Verify that the RJ-45 silver satin cable is plugged into the control port on the back of the ADTRAN DSU IQ. 2. If you are able to see the initial login screen but the remote configuration session fails, the screen shown in Figure 8 will continue to be displayed after pressing a key on the computer.
  • Page 7 There are four possible reasons that could cause a remote configuration session to fail: • The remote DSU IQ is not powered on or not connected to the frame relay circuit. • There is a problem with the frame relay circuit.
  • Page 8 The DLCI must be active in order for the remote configuration to work. If the status is I for inactive, the customer should contact the telephone company and report that their DLCI is inactive. If you experience any problems using your ADTRAN product, please contact ADTRAN Technical Support @ 888-423-8726...
  • Page 9 ADTRAN SPECIFICALLY DISCLAIMS ALL WARRANTIES, EXPRESSED OR IMPLIED, INCLUDING BUT NOT LIMITED TO, MERCHANTABILITY AND FITNESS FOR A PARTICULAR PURPOSE. IN NO EVENT SHALL ADTRAN BE LIABLE FOR ANY LOSS OR DAMAGE, AND FOR PERSONAL INJURY, INCLUDING BUT NOT LIMITED TO, COMPENSATORY, SPECIAL,...