Digital output
(NPN)
CK3M-series Programmable Multi-Axis Controller User's Manual Hardware (O036)
Internal common
Rated voltage
Current consumption
Operating load voltage
range
Maximum load current
Maximum inrush current
Leakage current
Residual voltage
ON/OFF response time
Isolation method
Load short-circuit preven-
tion
Circuit configuration
PNP type
24 VDC
NPN
12 to 24 VDC
40 mA max.
10.2 to 26.4 VDC
0.5 A/point, 2 A/Unit
4.0 A/point, 10 ms max.
0.1 mA max.
1.0 V max.
0.1 ms max./0.8 ms max.
Isolation by Photocoupler (between output and internal cir-
cuit)
Not provided
Internal
circuit
3 Configuration Units
IN00
IN01
IN15
G1
V2
OUT00
OUT01
OUT15
G2
3-47