Advertisement

6 Troubleshooting
 AbortAll
Register name
Description
Range
Details
Detection timing
Recovery
Effects
Cause and cor-
rection
Precautions/
Remarks
 NoClocks
Register name
Description
Range
Details
Detection timing
Recovery
Effects
Cause and cor-
rection
Precautions/
Remarks
6-14
Sys.AbortAll
Stop by Abort all input
0 to 1
0: No stop by Abort all input
1: Stopped by Abort all input, or stopped in the past by Abort all input.
With Abort all input
Cycle the power supply, or issue reset command ($$$)
Operation continues
Cause (Assumed cause)
Abort all was input.
None
Sys.NoClocks
Cannot detect a phase clock or a servo clock.
0 to 1
0: No error
1: Cannot detect a phase clock or a servo clock.
When power is turned ON or the Controller is reset.
Cycle the power supply, or issue reset command ($$$)
Cannot enable the motor.
Cause (Assumed cause)
The clock-related register is
overwritten by the user pro-
gram.
A Unit that supplies servo
clock and phase clock sig-
nals is installed to the Ex-
pansion Rack.
The CPU Unit or the CK3W
Unit has failed
None
CK3M-series Programmable Multi-Axis Controller User's Manual Hardware (O036)
Correction
None
Correction
If the error no longer occurs
after the re-initialization
command ($$$***) is exe-
cuted, review the user pro-
gram.
Install the Unit that supplies
clock signals to the CPU
Rack.
If this error persists even
after you make the above
corrections, replace the
CPU Unit or the CK3W
Unit.
Prevention
None
Prevention
None
None
None