Pin No.
Signal
10
OUT_COM1
11
NC
12
NC
13
NC
14
NC
15
NC
Shell
Shield
*1.
OUT0 is PWM output, and OUT1 is TCR output.
*2.
OUT1 is available with the CK3W-GC£200 Units only.
Dedicated Cable
The dedicated cable for wiring to the laser connector is provided as an option.
The laser connection side has discrete wires.
Perform wiring to match the laser specifications.
The cable model is as shown below.
Type
For laser connection CK3W-CAES03A 3 m
6
1
11
15
5
10
Type
Pin No. Cable color Mark
Pair 1 11
13
Pair 2 4
9
Pair 3 5
10
*1.
OUT0 is PWM output, and OUT1 is TCR output.
*2.
OUT1 is available with the CK3W-GC£200 Units only.
Note The cable shield is connected to the connector shell of the encoder connector.
Additional Information
You may use a self-made cable.
When you create a self-made cable, use a shielded twisted-pair cable to block the effects of
noise.
CK3M-series Programmable Multi-Axis Controller User's Manual Hardware (O036)
XY
Input/Output
Output
*1 *2
-
-
-
-
-
Model
Length
Signal
Blue
Black Not wired
Blue
Red
Not wired
Pink
Black OUT0
*1
Pink
Red
OUT_COM0
Green
Black OUT1
*1
Green
Red
OUT_COM1
3000
24AWG x 3 Pairs
*1 *2
*1 *2
5 Wiring
5
35
10
Shield
5-49