3
Establish an SSH connection, and execute the sync command from the terminal that you con-
nected to.
4
Wait for at least 5 seconds and turn OFF the power supply.
 Procedure to Download to the Built-in Flash Memory (Version 2.5 or Later)
For PMAC firmware revision version 2.5 or later, you can also use the following procedure to store
the user program into the built-in flash memory.
1
Download the user program from the Power PMAC IDE.
2
At the Power PMAC IDE terminal, enter Sys.SyncSave=1.
3
At the Power PMAC IDE terminal, execute the save command.
Wait until the save completed notification is displayed on the Power PMAC IDE.
4
At the Power PMAC IDE terminal, enter Sys.SyncSave=0.
5
Wait for at least 5 seconds and turn OFF the power supply.