Add a temperature offset of +10 °C to the thermocouple measurements.
x
IEEE-488
TC_OFFSET?
(Thermocouple Temperature Measurement Offset query) Returns the temperature offset
used for thermocouple measurements (±500 °C).
Responses:
<value> CEL
<value> FAR
Example:
TC_OFFSET? returns 1.000E+01,CEL
Returns 10 Celsius when a temperature offset of +10 °C has been added to the
thermocouple measurements.
x
IEEE-488
TC_OTCD
(Thermocouple Open Detection command) Activates or deactivates the open
thermocouple detection circuit in thermocouple measurement mode. Once set, the
Calibrator retains open thermocouple detection circuit setting until power off or reset.
Parameters: ON
OFF
Example:
TC_OTCD ON
Activate the open thermocouple detection circuit. If an open thermocouple is detected,
this condition is displayed on the front panel.
x
IEEE-488
TC_OTCD?
(Thermocouple Open Detection query) Returns the status of the open thermocouple
detection circuit in thermocouple measurement mode.
Responses:
ON
OFF
Example:
TC_OTCD? returns ON
Returns ON when the open thermocouple detection circuit is activated.
x
IEEE-488
TC_REF
(Thermocouple Reference command) Sets whether the internal temperature sensor (INT)
or an external reference value (EXT) is used for Thermocouple (TC) outputs and
measurements. If the first parameter is EXT, the second parameter must be the
temperature value to use as the reference for the thermocouple reference junction
temperature. Once set, the Calibrator retains reference setting until power off or reset.
Parameters: INT
EXT, <value of external reference> CEL (or FAR)
Example:
TC_REF EXT, 25.6 CEL
Set the thermocouple reference to external, with a value of 25.6 °C.
x
IEEE-488
TC_REF?
(Thermocouple Reference query) Returns the source and value of the temperature being
used as a reference for thermocouple simulation and measurement (in Celsius, CEL, or
Fahrenheit, FAR, depending on active units). The choices are Internal reference (INT) or
External reference (EXT).
x
x
RS-232
(offset in Celsius) (optional)
(offset in Fahrenheit) (optional)
x
x
RS-232
Sequential
(turn on thermocouple detection circuit) (default)
(turn off thermocouple detection circuit)
x
x
RS-232
Sequential
(thermocouple detection circuit is on)
(thermocouple detection circuit is off)
x
x
RS-232
Sequential
x
x
RS-232
Sequential
x
Sequential
Overlapped
x
Overlapped
x
Overlapped
x
x
Overlapped
x
x
Overlapped
Remote Commands
Commands
x
Coupled
x
Coupled
x
Coupled
Coupled
Coupled
6-41
6

Advertisement

Table of Contents
loading

This manual is also suitable for:

5522a5522a-pq5522a-pq/1g5522a/1ghz5522a-pq/6

Table of Contents