Viewing general Image quality information

1. On the Show settings menu, press the Down key four times, followed by
the Confirm key to select 'Image quality'.
The following screen will appear:
2. Press the Confirm key to select 'General'.
The general Image quality settings are displayed:
The following info is displayed:
• Film calibration setting: OFF/ON with the number of film packs
determining the calibration interval (if ON).
• Dmax upper tray: the maximum density for the upper input tray
resulting from the automatic film calibration.
• Dmax lower tray: the maximum density for the lower input tray
resulting from the automatic film calibration.
• TPH cleaning: the number of prints after the last thermal head
cleaning, and the number of prints to go before a new cleaning session
is necessary.
• TPH profile: the number of prints after the last thermal head profile
calibration and the number of prints to go before a new thermal head
profile calibration is necessary.
• Def. densitometer: shows the default densitometer that is used for the
calibrations.
3. Press the Confirm key to return to the Image quality menu.
4. In the Image quality menu, press the Escape key to return to the Show
settings menu.
DRY 3.4 | Advanced Operation (key-operator mode) | 19