Mitsubishi Electric s-MEXT-G00 006 Technical Manual page 61

Computer room air conditioner
Table of Contents

Advertisement

TM_s-MEXT_ME28relC_00_12_19_EN
N. Par.
Description
27.22
Offset start point (Cooling)
27.23
Offset end point (Cooling)
27.24
Maximum setpoint offset (Cooling)
27.25
Offset start point (Heating)
27.26
Offset end point (Heating)
27.27
Maximum setpoint offset (Heating)
30.01
Supervision presence configuration
30.02
BMS address configuration
BMS protocol configuration [0: Standard | 1: Modbus | 2: GSM Modem | 3: LON | 4: Bacnet | 5: TCP/IP | 6:
30.03
WinLoad]
30.04
BMS baud rate configuration [0: 1200 | 1: 2400 | 2: 4800 | 3: 9600 | 4: 19200 | 5: 38400]
30.05
ON/OFF configuration from BMS [0: Disabled | 1: Enabled]
30.06
Summer/Winter switch configuration from BMS [0: Disabled | 1: Enabled]
30.09
Enable for adjustment according to the temperature supplied from BMS [0: Disabled | 1: Enabled]
30.11
Enable the stop of direct Freecooling from supervisor [0: Disabled | 1: Enabled]
31.01
Alarm A contact status configuration [0: NO | 1: NC]
31.02
Alarm B contact status configuration [0: NO | 1: NC]
31.03
Fire/smoke alarm addressing on digital output [0: A | 1: None | 2: B]
31.04
Phase Sequence alarm addressing on digital output [0: A | 1: None | 2: B]
31.10
Air flow alarm addressing on digital output [0: A | 1: None | 2: B]
31.11
Ambient air temperature probe alarm addressing on digital output [0: A | 1: None | 2: B]
31.12
Ambient humidity probe alarm addressing on digital output [0: A | 1: None | 2: B]
31.13
Differential pressure probe alarm addressing on digital output [0: A | 1: None | 2: B]
31.14
Delivery air temperature probe alarm address on digital output [0: A | 1: None | 2: B]
31.16
External air temperature probe alarm addressing on digital output [0: A | 1: None | 2: B]
31.18
Electric heater alarm addressing on digital output [0: A | 1: None | 2: B]
31.19
T+H probe offline alarm addressing on digital output [0: A | 1: None | 2: B]
31.23
Inverter IO expansion offline alarm addressing on digital output [0: A | 1: None | 2: B]
31.24
Network transducer offline alarm addressing on digital output [0: A | 1: None | 2: B]
31.25
Humidifier CPY offline module alarm addressing [0: A | 1: None | 2: B]
31.42
Humidifier life expired alarm addressing on digital output [0: A | 1: None | 2: B]
31.43
Humidifier discharge alarm addressing on digital output [0: A | 1: None | 2: B]
31.44
Humidifier insufficient water alarm addressing on digital output [0: A | 1: None | 2: B]
31.45
Humidifier low current alarm addressing on digital output [0: A | 1: None | 2: B]
31.46
Humidifier high current alarm addressing on digital output [0: A | 1: None | 2: B]
31.47
Humidifier generic alarm addressing on digital output [0: A | 1: None | 2: B]
31.49
Flooding alarm addressing on digital output [0: A | 1: None | 2: B]
31.50
LAN alarm addressing on digital output [0: A | 1: None | 2: B]
31.51
Low temperature alarm addressing on digital output [0: A | 1: None | 2: B]
31.52
High temperature alarm addressing on digital output [0: A | 1: None | 2: B]
31.53
Low humidity alarm addressing on digital output [0: A | 1: None | 2: B]
31.54
High humidity alarm addressing on digital output [0: A | 1: None | 2: B]
Technical manual
TRANSLATION OF THE ORIGINAL INSTRUCTIONS
61
Default
U.M.
Min.
0.0
°C
-30.0
10.0
°C
P 27.22
0.0
°C
-30.0
0.0
°C
-30.0
10.0
°C
P 27.25
0.0
°C
-30.0
0
-
0
11
-
1
1
-
0
4
-
0
0
-
0
0
-
0
0
-
0
0
-
0
0
-
0
0
-
0
0
-
0
0
-
0
0
-
0
0
-
0
0
-
0
0
-
0
0
-
0
0
-
0
0
-
0
0
-
0
0
-
0
0
-
0
0
-
0
0
-
0
0
-
0
0
-
0
0
-
0
0
-
0
0
-
0
0
-
0
0
-
0
0
-
0
0
-
0
0
-
0
0
-
0
Max.
P 27.23
50.0
50.0
P 27.26
50.0
50.0
1
207
6
5
1
1
1
1
1
1
2
2
2
2
2
2
2
2
2
2
2
2
2
2
2
2
2
2
2
2
2
2
2
2
2

Hide quick links:

Advertisement

Table of Contents
loading

This manual is also suitable for:

S-mext-g00 044

Table of Contents