Mask of the terminal
ACTIVE FUNCTIONS
DELAY FOR TIME
OBSERVATION
24.0 °C 15.0 °C
35.0 °C
AUXILIARY T-H PROBE
Addr. 129
24.0 °C
50.0 %
Status:Offline
REQUEST STATUS
Cooling request: 100%
Step request:
11
Waiting:
NONE
PAC-IF013B-E MASTER
Active step:
11
Mode:
COOLING
Status:Online
PAC-IF013B-E SLAVE1
Active step:
11
Mode:
COOLING
Status:Online
0 08.0bar 08.0bar
03.3°C
03.3°C
LAN 1: 2: 3:
4: 5: 6:
7: 8: 9:
10:
Technical manual
Description
Mask that displays the active functions of the unit
Visible only when certain functions are active
Active probe value display mask
Return temperature probe
Delivery temperature probe
External temperature probe
Mask that displays the value of the serial auxiliary probe (address 129).
Visible if the probe is configured
Mask displaying the requests of cold and steps sent to the PCA-IF013B-E card
It also shows if the system is waiting for the expiry of a time delay before sending the steps to the Master PAC-IF013B-E card:
[NONE]
[SHORT WAIT]
[LONG WAIT]
[CHANGING MODE]
[MIN T.OFF]
Master PAC-IF013B-E status
Pressing [ENTER] will take to the section containing additional Master PAC-IF card information
In case of alarm, the
icon will flash showing the "PAC-IF code:" message followed by the alarm code from the PAC-IF card.
For additional information on the meaning of the code, see the "Event Mask" chapter.
Slave 1 PAC-IF013B-E status
Pressing [ENTER] will take to the section containing additional Slave 1 PAC-IF card information
In case of alarm, the
icon will flash showing the "PAC-IF code:" message followed by the alarm code from the PAC-IF card.
For additional information on the meaning of the code, see the "Event Mask" chapter.
Mask for the display of the values of the active probes and their conversions into temperature
Circuit 1 low pressure switch
Circuit 2 low pressure switch
Visible if the local network (LAN) is configured Local network (LAN) status display mask. This mask is displayed only at the Master
unit (LAN address=1).
Unit operating
Unit in stand by
Unit not operating
Unit with Hot-Spot protection
When enabled it is possible to view the status of the ADL LAN function:
ADL enabled
ADL operating limit reached
No delay
Short delay (300s / 5min)
Long delay (600s / 10min)
Cycle inversion/mode change (120 s / 2min)
Minimum Off (120s / 2min)
Unit in rescue mode
Unit with Cold-Spot protection