1: Reverse Run - YASKAWA Varispeed V7 Instruction Manual

Compact general-purpose inverter
Table of Contents

Advertisement

No.
Terminal
n050
n051
n052
n053
n054
(See note.)
n055
(See note.)
n056
(See note.)
Note: Terminals S5 through S7 can be used only from DeviceNet communica-
tions. There are no corresponding external terminals.
Terminal Functions for 3-wire Sequence Selection
When 0 is set for terminal S3 (n052), terminal S1 is the RUN command,
terminal S2 is the STOP command, and terminal S3 is the FWD/REV
RUN command.
STOP SW
(NC contact)
WARNING
Factory Settings
Factory Setting
S1
1
S2
2
S3
3
S4
5
S5
6
S6
7
S7
10
RUN SW
(NO contact)
RUN command
(Run when closed)
STOP command
(Stop when open)
FWD/REV run selection
To select the 3-wire sequence, set terminal S3 (n052)
to 0.
Failure to observe this warning may result in injury.
7. Programming Features
FORWARD RUN command (2-
wire sequence)
REVERSE RUN command (2-
wire sequence)
External fault
Fault reset
Multi-step speed reference 1
Multi-step speed reference 2
JOG command
Varispeed V7
FWD run when open
REV run when closed
Function
159