YASKAWA Varispeed V7 Instruction Manual page 107

Compact general-purpose inverter
Table of Contents

Advertisement

In-
At-
stance
tribute
01
07
08
09
0A
0B
0C
0D
106
Name
Contents
Running
Indicates the
1
Inverter's operat-
ing status.
00: Stopped, oper-
ating in reverse, or
applying DC injec-
tion braking (Re-
verse RUN
command ON).
01: Operating for-
ward or applying
DC injection brak-
ing (Reverse RUN
command OFF).
Running
Indicates the
2
Inverter's operat-
ing status.
00: Stopped, oper-
ating forward, or
applying DC injec-
tion braking (Re-
verse RUN
command OFF).
01: Operating in
reverse or apply-
ing DC injection
braking (Reverse
RUN command
ON).
Ready
Indicates the
Inverter's prepara-
tion status.
00: Fault detected
or initializing.
01: Preparations
for operation com-
pleted.
Faulted
Indicates that the
Inverter detected
a fault.
00: Normal
01: Fault detected.
Warning
Indicates that the
Inverter detected
a warning.
00: Normal
01: Warning de-
tected.
Fault
Resets the
Reset
Inverter from fault
status.
00: ---
01: Reset fault.
Fault
The fault code in-
Code
dicates which fault
was detected by
the Inverter. (See
note 3.)
Setting
Factory Set-
Range
ting (Hex)
---
00
---
00
---
00
---
00
---
00
00,01
00
---
0000
Read Write
Size
OK
---
Byte
OK
---
Byte
OK
---
Byte
OK
---
Byte
OK
---
Byte
OK
OK
Byte
OK
---
Word