YASKAWA Varispeed V7 Instruction Manual page 66

Compact general-purpose inverter
Table of Contents

Advertisement

6. Operating with DeviceNet Communications
• Input (Master → Inverter) Instance 100 (64 Hex)
Byte
Bit 7
Bit 6
0
Function Code
1
Register Number (High Byte)
2
Register Number (Low Byte)
3
Register Data (High Byte)
4
Register Data (Low Byte)
Data
Name
Byte 0
Function
Code
Bytes
Register
1 and 2
Number
Bytes
Register
3 and 4
Data
• Output (Inverter → Master) Instance 150 (96 Hex)
Byte
Bit 7
Bit 6
0
Function Code
1
Register Number (High Byte)
2
Register Number (Low Byte)
3
Register Data (High Byte)
4
Register Data (Low Byte)
Bit 5
Bit 4
Bit 3
Set the MEMOBUS (command mes-
sage) function code.
03 Hex: Read
10 Hex: Write
00 Hex: Do not execute.
Set the Inverter's MEMOBUS register
number.
Set the write data when executing a ME-
MOBUS WRITE command.
Bit 5
Bit 4
Bit 3
Bit 2
Bit 1
Contents
Bit 2
Bit 1
Bit 0
Bit 0