6. Operating with DeviceNet Communications
• Input (Master → Inverter) Instance 102 (66 Hex)
Byte
Bit 7
Bit 6
0
---
Termi-
nal S7*
1
Termi-
Termi-
nal P2
nal P1
2
Speed Reference (Low Byte)
3
Speed Reference (High Byte)
4
Acceleration Time 1 (Low Byte)
5
Acceleration Time 1 (High Byte)
6
Deceleration Time 1 (Low Byte)
7
Deceleration Time 1 (High Byte)
Data
Name
Byte 0,
Run Fwd
bit 0
Byte 0,
Run Rev
bit 1
Byte 0,
Terminal
bit 2
S3
Bit 5
Bit 4
Bit 3
Termi-
Termi-
Termi-
nal S6*
nal S5*
nal S4
Termi-
---
---
nal
MA*
Runs the Inverter forward.
0: Stop.
1: Run forward.
Runs the Inverter in reverse.
0: Stop.
1: Run in reverse.
Inputs the function set for the Inverter's
multi-function input terminal S3. Set the
function of multi-function input terminal
S3 with Inverter constant n052.
0: Terminal S3 function OFF
1: Terminal S3 function ON
Bit 2
Bit 1
Termi-
Run
nal S3
Rev
---
Fault
Reset
Contents
Bit 0
Run
Fwd
Exter-
nal
Fault
73