Byte
4
Register Number (Low Byte)
5
Register Number (High Byte)
6
Register Data (Low Byte)
7
Register Data (High Byte)
Data
Byte 0,
bit 0
Byte 0,
bit 1
Byte 0,
bit 2
Byte 0,
bit 3
Byte 0,
bit 4
80
Bit 7
Bit 6
Bit 5
Name
Run Fwd
Run Rev
Terminal
S3
Terminal
S4
Terminal
S5*
Bit 4
Bit 3
Runs the Inverter forward.
0: Stop.
1: Run forward.
Runs the Inverter in reverse.
0: Stop.
1: Run in reverse.
Inputs the function set for the Inverter's
multi-function input terminal S3. Set the
function of multi-function input terminal
S3 with Inverter constant n052.
0: Terminal S3 function OFF
1: Terminal S3 function ON
Inputs the function set for the Inverter's
multi-function input terminal S4. Set the
function of multi-function input terminal
S4 with Inverter constant n053.
0: Terminal S4 function OFF
1: Terminal S4 function ON
Inputs the function set for Inverter con-
stant n054 (Multi-function Input Selec-
tion 5.)
0: Terminal S5 function OFF
1: Terminal S5 function ON
Bit 2
Bit 1
Contents
Bit 0