YASKAWA Varispeed V7 Instruction Manual page 79

Compact general-purpose inverter
Table of Contents

Advertisement

Data
Byte 0,
bit 7
Byte 1,
bit 0
Byte 1,
bit 1
Byte 1,
bit 2
Byte 1,
bit 3
Byte 1,
bit 4
Byte 1,
bit 5
78
Name
Faulted
Indicates that the Inverter detected a
fault.
0: Normal
1: Fault detected.
OPE
Indicates that the Inverter detected a
MEMOBUS constant setting error
(OPE).
0: Normal
1: OPE (OP1 to OP5) detected.
UV
Indicates that the Inverter detected an
undervoltage error.
0: Normal
1: UV detected.
Local/Re-
Indicates which RUN command input
mote
has been selected in the Inverter.
0: A RUN command input other than
1: The RUN command input from
Terminal
Indicates the output status of Inverter
MA*
multi-function output terminal MA.
0: Terminal MA OFF
1: Terminal MA ON
Terminal
Indicates the output status of Inverter
P1
multi-function output terminal P1.
0: Terminal P1 OFF
1: Terminal P1 ON
Terminal
Indicates the output status of Inverter
P2
multi-function output terminal P2.
0: Terminal P2 OFF
1: Terminal P2 ON
Contents
DeviceNet is enabled.
DeviceNet is enabled.