Data
Byte 0,
bit 1
Byte 0,
bit 2
Byte 0,
bit 3
Byte 0,
bit 4
Byte 0,
bit 5
Byte 0,
bit 6
84
Name
ZSP
Indicates the Inverter's operating status.
0: Operating forward or in reverse.
1: Stopped or applying DC injection
Rev Run-
Indicates the Inverter's operating status.
ning
0: Operating forward, stopped (Reverse
1: Operating in reverse, stopped
Reset
Indicates the input status of the
Inverter's RESET signal.
0: ---
1: RESET signal being input.
At Refer-
Indicates that the Inverter's frequency
ence
match was detected.
0: Stopped, accelerating, or decelerat-
1: Frequency matches.
Ready
Indicates the Inverter's preparation sta-
tus.
0: Fault detected or initializing.
1: Preparations for operation completed.
Warning
Indicates that the Inverter detected a
warning.
0: Normal
1: Warning detected.
Contents
braking.
RUN command OFF), or applying DC
injection braking (Reverse RUN com-
mand OFF).
(Reverse RUN command ON), or
applying DC injection braking
(Reverse RUN command ON).
ing.

Advertisement