Return the BCM50 system to operation

1
Check the Power and Status LEDs on the Main Unit. After the BCM50 has finished starting
up, both LEDs should be lit solid and green. If either LED is not lit solid and green, there is a
problem with the Main Unit. Refer to
description of the LED states.
2
If this system has a BCM50 Expansion Unit, check the Power and Status LEDs on the media
bay module that is inserted in the BCM50 Expansion Unit. Both LEDs should be lit solid and
green. If either LED is not lit solid and green, there is a problem with the media bay module or
the BCM50 Expansion Unit. Refer to
only)" on page 76
3
If this system has a second BCM50 Expansion Unit, check the Power and Status LEDs on the
second media bay module.
4
If there is a recent backup of the BCM50 programming, use Element Manager to restore the
programming. Go to step 8.
If there is not a recent backup, continue with the next step.
5
Set the basic configuration parameters. Refer to
page 147
for more information.
Warning: When you restart the system, all IP clients/voice mail and VoIP ports
are not available until the system services restart.

Next step

Once you have returned the BCM50 system to operation, you can test the system. Refer to
and troubleshoot the BCM50 system" on page 177
system.
"System status LEDs" on page 71
"Media bay module LEDs (BCM50 Expansion Units
for a detailed description of the LED states.

Return the BCM50 system to operation

"Configure the basic BCM50 parameters" on
for information about testing the BCM50
Replace an internal component
215
for a detailed