Insert the new fan

To insert the new BCM50 fan:
1
Attach one end of a grounding strap to your wrist and the other end to a grounded metal
surface.
2
Insert the new fan into the fan slot in the bottom of the BCM50 case.
Note: Ensure the label of the new fan faces the back of the BCM50 unit. Airflow
is out of the chassis as indicated by the arrows imprinted on the fan.

Figure 75 Fan slot and cable header

3
Connect the fan cable to the header on the Compact Services Card (CSC). Make sure that the
raised edge on the fan cable connector faces the plastic tab on the header. Refer to the previous
diagram for the location of the header.
Note: Do not force the cable.
The connector on the fan cable is designed to prevent the cable from being
inserted backwards. If the cable does not insert properly, check that the raised
edge on the fan cable connector faces the plastic tab on the header.
4
Continue to the next step,
Cable header
"Close the BCM50 case" on page
Insert the new component
Fan slot
213.