Figure 42 Switches On The Media Bay Module - Nortel BCM50 Installation And Maintenance Manual

Table of Contents

Advertisement

Figure 42 Switches on the media bay module

Back of the media bay module
Verify that the dip switches for your MBMs are in the default factory positions as stated below.
Caution: The media bay module (MBM) dip switches must remain in their
default factory position. Any required modifications to the MBM settings are
made through the software.
If you are installing a DTM, DDIM, BRIM, 4X16, DSM16, DSM32, or ASM8, ensure that the
switches are all on. This is the default setting for the MBM switches. After you have set the
switches, proceed to
If you are installing a GATM4 or GATM8, check that the switches on both the right and left sets of
dip switches are all on. This is the default setting for the MBM switches. After you have set the
switches, proceed to
If you are installing a GASM8:
1
For the dip switches on the left side, at the rear of the module, set all of the switches to on.
Underside of the
media bay module
6 5 4 3 2 1
dip switches
Rear view of the media bay module
"Install a media bay module in a BCM50 Expansion Unit" on page
"Install a media bay module in a BCM50 Expansion Unit" on page
Set the media bay module switches
Off
On
On
1 2 3 4 5 6
Off
Install a BCM50 Expansion Unit
111
Module is
right-side up
112.
112.