2
Ensure that the analog port terminates correctly in 600 ohms:
•
Replace the analog telephone with the test set
•
Use RECEIVE/600 OHM/HOLD mode on the test set
3
Ensure that the test set connects in parallel to the service line before removing the analog
telephone or the line drops.
4
Remove the single-line telephone.
5
Measure the 1 kHz tone at the far end of the analog port, which is where the analog loop ends
and where the analog device connects.)
Note: The tone must be greater than - 10 dB (for example: - 9 dB is acceptable).
For analog device to CO measurement
Use this procedure to measure the insertion loss from the analog device to the CO.
1
Establish a connection to a silent termination on the CO service line with an analog telephone
attached to the ATA 2.
2
Make sure the analog port terminates correctly in 600 ohms by:
•
Replace the analog telephone with the test set
•
Use TRANSMIT/600 OHM/HOLD mode on the test set
3
Make sure the test set connects in parallel to the service line before removing the analog
telephone or the line drops.
4
Remove the analog telephone.
5
Introduce a 1 kHz tone into the analog line at - 10 dBm, and measure the level at the CO
exchange.
Note: The difference in levels is the transmit loss and must be less than 10 dB
(for example, 9 dB is acceptable).
Configuring the ATA 2
Configure the ATA 2 using the BCM50 Element Manager. For detailed configuration information
refer to the BCM50 Administration Guide
(N0xxxxxxx).
Configuring the ATA 2
Install analog terminal adapters
143