Service and maintenance
10.2 Error messages
10.2.2
Reading out error messages using the WBM
Reading out error messages using the WBM
All the diagnostics messages of the communication module are entered in the "Log" if a
check mark was set for "ERRORS" in the WBM configuration in "Settings - General". You will
find further information on the "Log" in the section "The "Diagnostics - Log" menu item
(Page 82)".
10.2.3
OPC UA error messages
The following table lists the OPC UA-specific error codes.
Table 10- 8
OPC UA error messages of the communications module
AutoId
OPC UA
status
status
1
good
1
good
1
good
1
good
1
good
3
good
142
AutoId
text
MISC_ERROR_
TOTAL
MISC_ERROR_
TOTAL
MISC_ERROR_
TOTAL
MISC_ERROR_
TOTAL
MISC_ERROR_
TOTAL
PERMISSON_
ERROR
Error description
General error
Firmware error
•
Possible cause: The firmware update was not run complete-
ly.
Internal communications error of the communications mod-
•
ule/reader
–
Connector contact problem on the communications
module / reader
–
Hardware of the communications module/reader has a
defect; → Send in communications module/reader for re-
pair
–
Start "INIT" after correcting the error
Internal monitoring error of the communications mod-
•
ule/reader
–
Program execution error on the communications module
/ reader
–
Turn the power supply of the communications mod-
ule/reader off and on again
–
Start "INIT" after correcting the error
The inventory command failed.
Enabling write protection on the transponder has failed.
The "Kill" command failed.
The transponder is read/write-protected.
Operating Instructions, 12/2019, C79000-G8976-C578-01
SIMATIC RF166C