Programming via OPC UA
9.2 OPC UA variables
9.2.3
SimaticIdentModelVersion
Table 9- 5
Path
Data type
Access
Description
Possible values
9.2.4
CommonSettings
You can make basic settings on the communication module using these variables.
Table 9- 6
Path
Data type
Access
Description
Possible values
106
SimaticIdentModelVersion
Root/Objects/DeviceSet/Read_point_x/RuntimeParameters/Sima
ticIdentModelVersion
String
R
Indicates the version of the OPC UA module.
Example:
V1.1.0
CodeTypes
Root/Objects/DeviceSet/Read_point_x/RuntimeParameters/Com
monSettings/CodeTypes
UInt32
R/W
Definition of the data type for all AutoID identifiers in "AutoID
Standard".
The setting has an effect specifically on the data type of the
"LastScanData", variable, the "Identifier" diagnostics variable and
the "ScanData" union used for the "Identifier" in methods or
events.
The types "String", "ByteString" and "ScanDataEpc" are support-
ed. The type definition of "CodeTypes" is "MultiStateDiscrete-
Type". This means that the variable has an "Enum" that indicates
the supported data types as "Property".
•
•
•
0: ByteString
1: String
2: ScanDataEpc
Operating Instructions, 12/2019, C79000-G8976-C578-01