Siemens SIMATIC RF166C Operating Instructions Manual page 139

Hide thumbs Also See for SIMATIC RF166C:
Table of Contents

Advertisement

"ER"
Block (hex)
LED
--
0xE5FE0600
--
0xE5FE0700
--
0xE5FE0800
--
0xE5FE0900
--
0xE5FE0A00
--
0xE5FE0B00
--
0xE5FE0C00
3x
0xE5FE8100
3x
0xE5FE8200
3x
0xE5FE8300
3x
0xE5FE8400
4x
0xE6FE0100
4x
0xE6FE0200
SIMATIC RF166C
Operating Instructions, 12/2019, C79000-G8976-C578-01
Error description
Invalid data block length (DBL) on the reader/communication module
Invalid data block length (DBL) in the Ident profile
The previous command is still active or the buffer is full.
A new command was sent to the reader or communication module although the last command is
still active.
The active command can only be aborted with "INIT".
Before a new command can be started, "DONE bit = 1" must be set (exception "INIT").
Two Ident profile calls were assigned the same "HW_ID", "CM_CHANNEL" and "LADDR"
parameter settings.
Two Ident profile calls are using the same pointer.
After eliminating the error, execute the "INIT" command.
When working with command repetition (e.g., fixed code transponder), no data is being
fetched from the transponder. The data buffer on the reader/communication module has
overflowed. Transponder data has been lost.
The reader or the communication module runs a hardware reset ("INIT_ACTIVE" set to "1"). The
Ident profile expects an "INIT" (bit 15 in the cyclic control word).
The "CMD" command code and the relevant acknowledgment do not match. This can be a soft-
ware error or synchronization error that cannot occur in normal operation.
Incorrect sequence of acknowledgement frames (TDB / DBN)
Synchronization error (incorrect increment of "AC_H / AC_L" and "CC_H / CC_L" in the cyclic
control word). "INIT" had to be executed.
Communication error between reader and communication module
Access denied
Communication error between reader and communication module
Resource is occupied
Communication error between reader and communication module
Functional error of the reader interface
Communication error between reader and communication module
Other faults/errors
Unknown command
An uninterpretable XML command was sent to the reader or the Ident profile sends an uninter-
pretable command to the reader.
Possible causes:
The "AdvancedCmd" block was supplied with an incorrect "CMD".
The "CMD" input of the "AdvancedCmd" block was overwritten.
Invalid command index (CI)
Service and maintenance
10.2 Error messages
139

Advertisement

Table of Contents
loading

Table of Contents