Siemens SIMATIC RF166C Operating Instructions Manual page 121

Hide thumbs Also See for SIMATIC RF166C:
Table of Contents

Advertisement

Table 9- 34
Data type
Description
Possible values
Table 9- 35
Data type
Description
Possible values
Table 9- 36
Data type
Description
Possible values
Table 9- 37
Data type
Description
Possible values
SIMATIC RF166C
Operating Instructions, 12/2019, C79000-G8976-C578-01
Antenna
Int32
The antenna via which the transponder was accessed with the
last command.
Two-digit number
The first digit stands for the read point index, the second digit for
the antenna index within the read point.
Example:
CurrentPowerLevel
Int32
Power with which the last command was executed on the tran-
sponder. This variable is only supported by UHF readers.
Decimal number for the power in [dB]
Increment: 0.25 dB
PC
UInt16
Protocol Control Word of the transponder that was accessed last.
This variable is only supported by UHF readers.
Example:
3000
Polarization
String
Polarization with which the last command was executed on the
transponder. This variable is only supported by UHF readers.
Read point 1, antenna 1: 11
Read point 2, antenna 1: 21
0
5.00 ... 33.00
Default
Circular
Linear_vertical
Linear_horizontal
Programming via OPC UA
9.3 OPC UA events
121

Advertisement

Table of Contents
loading

Table of Contents