Reading Out Error Messages Using The Wbm; Xml Error Messages - Siemens SIMATIC RF185C Operating Instructions Manual

Hide thumbs Also See for SIMATIC RF185C:
Table of Contents

Advertisement

Service and maintenance
9.2 Error messages
"ER"
Block (hex)
LED
4x
0xE6FE8500
4x
0xE6FE8600
4x
0xE6FE8700
4x
0xE6FE8800
4x
0xE6FE8900
4x
0xE6FE8A00
4x
0xE6FE8B00
--
0xE7FE0100
--
0xE7FE0200
--
0xE7FE0300
--
0xE7FE0400
--
0xE7FE0500
--
0xE7FE0600
--
0xE7FE0700
--
0xE7FE0800
--
0xE7FE0900
--
0xE7FE0A00
"--" means that the error is not displayed by the LEDs.
9.2.2

Reading out error messages using the WBM

All the diagnostics messages of the communication module are entered in the "Log" if a check
mark was set for "ERRORS" in the WBM configuration in "Settings - General". You will find
further information on the "Log" in the section "The "Diagnostics - Log" menu item (Page 98)".
9.2.3

XML error messages

A list of the possible XML error codes can be found in the "XML programming for SIMATIC
Ident (https://support.industry.siemens.com/cs/ww/en/view/109781631)" manual.
136
Error description
The command or the frame has an invalid format.
The "Inventory" command failed.
Read access to the transponder has failed.
Write access to the transponder has failed.
Writing the EPC ID/UID on the transponder has failed.
Enabling write protection on the transponder has failed.
The "Kill" command failed.
In this state, only the "Reset_Reader" ("WRITE-CONFIG") command is permitted.
The "CMD" command code is not permitted.
The value of the "LEN_DATA" parameter of the command is too long and does not match the
global data reserved within the send data buffer (TXBUF).
The receive data buffer (RXBUF) or the send data buffer (TXBUF) is too small, the buffer created at
TXBUF/RXBUF does not have the correct data type or the parameter "LEN_DATA" has a negative
value.
Possible cause / action to be taken:
Check whether the buffers TXBUF/RXBUF are at least as large as specified in "LEN_DATA".
With S7-1200/1500:
In the Ident profile, only an "Array of Byte" may be created for TXBUF and RXBUF.
In the "Reader_Status" block, only an "Array of Byte" or the corresponding data types
("IID_TAG_STATUS_XX_XXX" or "IID_READER_STATUS_XX_XXX") may be created
Only an "INIT" command is permitted as the next command. All other commands are rejected.
Wrong data record index of an acyclic data record
Permitted index is in the ranges "101 ... 108" and "-20401 ... -20418".
The reader or communication module does not respond to "INIT" ("INIT_ACTIVE" is expected in the
cyclic status message).
The next steps:
Check the address parameter "LADDR".
Timeout during "INIT" (60 seconds)
Command repetition is not supported.
Error during the transfer of the PDU (Protocol Data Unit).
SIMATIC RF185C, RF186C, RF188C, RF186CI, RF188CI
Operating Instructions, 03/2022, C79000-G8976-C512-04