Siemens SIMATIC RF166C Operating Instructions Manual page 113

Hide thumbs Also See for SIMATIC RF166C:
Table of Contents

Advertisement

Table 9- 18
Path
Data type
Access
Description
Possible values
Table 9- 19
Path
Data type
Access
Description
Possible values
SIMATIC RF166C
Operating Instructions, 12/2019, C79000-G8976-C578-01
CurrentPowerLevel
Root/Objects/DeviceSet/Read_point_x/RuntimeParameters/Diag
nosis/LastAccess/Rfid/CurrentPowerLevel
Int32
R
Diagnostics on the last transponder access
Outputs the power with which the last command was executed
on the transponder. This variable is only supported by UHF
readers.
The prerequisite is that the "Parallel" or "Diagnostics" option is
set in the WBM.
Decimal number for the power in [dB]
Increment: 0.25 dB
PC
Root/Objects/DeviceSet/Read_point_x/RuntimeParameters/Diag
nosis/LastAccess/Rfid/PC
UInt16
R
Diagnostics on the last transponder access
Outputs the protocol control word of the transponder that was
accessed last. This variable is only supported by UHF readers.
The prerequisite is that the "Parallel" or "Diagnostics" option is
set in the WBM.
Example:
3000
0
5.00 ... 33.00
Programming via OPC UA
9.2 OPC UA variables
113

Advertisement

Table of Contents
loading

Table of Contents